Status = In Press
Subject = Q Science / természettudomány: QC Physics / fizika: QC04 Electricity. Magnetism. Electromagnetism / villamosság, mágnesesség, elektromágnessesség Type = Article |
Cím: |
An MgB2 superconducting shield prototype for the Future Circular Collider septum magnet
|
Létrehozó: |
Barna, Daniel
Giunchi, Giovanni
Novak, Martin
Brunner, Kristof
Nemet, Aniko
Petrone, Carlo
Atanasov, Miroslav Georgiev
Bajas, Hugues
Feuvrier, Jerome
|
Dátum: |
2019-02-02
|
Téma: |
QC04 Electricity. Magnetism. Electromagnetism / villamosság, mágnesesség, elektromágnessesség
|
Tartalmi leírás: |
A passive superconducting shield was previously
proposed to realize a high-field (above 3 T) septum magnet
for the Future Circular Collider proton-proton ring (FCC-hh).
This paper presents the experimental results of a potential shield
material, MgB2 at a temperature of 4.2 K. A cylindrical shield
with a wall thickness of 8.3 mm was manufactured by the reactive
liquid magnesium infiltration technique using extra large grain
(∼160 µm) boron precursor, and tested in a transverse magnetic
field. The shield was stable against flux jumps on the virgin
curve, but suffered from flux jumps at low field levels after
high-field exposure. The tube could shield a magnetic field of
2.75 T on its surface before field penetration to its interior.
Parameters of the critical current density of the material could be
estimated from simulations, which indicate a steeper Jc(B) curve
than observed previously for large grain (∼100 µm) MgB2, and
predict a slightly better shielding performance (3 T) with an ideal
geometry. Relaxation of the shielding currents is at an acceptable
level. We estimate that a self-supporting shield of a wall thickness
of 14 mm could be adequate for the construction of a 3 T septum
magnet, if the flux jump problem can be solved. This thickness
would correspond to a total septum thickness (including beam
pipes, etc) of around 22 mm, which is an acceptable figure for
the FCC-hh.
|
Nyelv: |
angol
|
Típus: |
Article
PeerReviewed
info:eu-repo/semantics/article
|
Formátum: |
text
|
Azonosító: |
Barna, Daniel and Giunchi, Giovanni and Novak, Martin and Brunner, Kristof and Nemet, Aniko and Petrone, Carlo and Atanasov, Miroslav Georgiev and Bajas, Hugues and Feuvrier, Jerome (2019) An MgB2 superconducting shield prototype for the Future Circular Collider septum magnet. IEEE Transactions on Applied Superconductivity. p. 1. ISSN 1051-8223 (In Press)
|
Kapcsolat: |
doi:10.1109/TASC.2019.2920359
312453
|
Létrehozó: |
info:eu-repo/semantics/restrictedAccess
|